- four different keypads available
- connect up to 8 keypads to panel
| - |
SG-P832-08 ........ standard 8 zone LED keypad |
| - |
SG-P832-16 ........ standard 16 zone LED keypad |
| - |
SG-P832-32 ........ standard 32 zone LED keypad |
| - |
SG-P832-LCD .... alphanumeric keypad |
- expand from 8 zones to 32 zones
- 2 partitions
Hard Wire
| - |
SG-P5108 ...... 8 zone expansion module |
- |
SG-P5108D ..16 zone expansion module utilizing zone doubling |
Wireless
| - |
SG-P5132-900 ... wireless zone expansion module |
- |
connect up to 32 wireless zones |
- up to 4 high current outputs
| - |
SG-P5204 ... 4 output high current SG-P5204 ... power supply module |
|
SG-P5204 ... 1 output fully supervised SG-P5204 ... for siren output |
- up to 8 voltage outputs
| - |
SG-P5208 ... 8 output transistor switch module (50 mA) |
- supports all major formats including SIA and Contact ID
- LINKS cellular communication
- event initiated personal paging
- Downlook video alarm verification
- 3 phone numbers, 2 account numbers
- supports Central Station Two Way Voice and Home Intercom features
|
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
- 4 wire communications bus (KEYBUS)
- connect up to 8 keypads to panel
| - |
connect modules up to 1000' (330m) from control panel |
| - |
up to 1.5A auxiliary power |
| - |
SG-P5204... 4 output high current power supply module provides up to 1 A auxiliary power |
| - |
main panel provides up to 500mA auxiliary power |
- up to 32 fully programmable zones
| - |
8 zones on main control panel (16 with zone doubler option) |
| - |
hard wire zones and wireless expansion |
| - |
all zones programmable as burglary or fire |
| - |
assign zones to one or both partitions |
| - |
zone options include : End of Line (EOL) resistor, Double EOL resistor, Normally Closed loops or Zone Doubling
|
| - |
27 programmable zone types |
- 2 partitions
| - |
most features programmable by partition |
| - |
32 ... 4 or 6 digit access codes assignable to one or both partitions |
| - |
1 system master code, 2 partition master codes, and 2 duress codes |
- 128 event buffer
| - |
all events automatically stored with time and date stamp to buffer |
| - |
events can be printed on-site, viewed through the LCD Keypad or DLS software |
- alarm output
| - |
bell output... 700mA @ 12VDC, PTC protected |
| - |
additional supervised siren output using SG-P5204 power supply module, 1 A @ 12VDC, PTC protected |
- programmable voltage outputs
| - |
main panel PGM2... high current switch to ground (can also be used for 2 wire smoke) |
| - |
main panel PGM1 ... low current, 50 mA @ 12 VDC |
| - |
additional low current voltage outputs using SG-P5208 output module... 50 mA @ 12 VDC |
| - |
additional high current voltage outputs using SG-P5204 power supply module... 1.OA @ 12VDC |
| - |
16 programmable output options |
|
|
|
|
- upload/download capability
| - |
program system using DLS software
|
| - |
view status and trouble conditions
|
| - |
view 128 event buffer
|
- power capacity
| - |
500mA @ 12.5VDC (400mA for UL applications)
|
| - |
separately fused battery and bell output
|
| - |
positive temperature coefficient (PTC) AUX & Bell output protection
|
| - |
electronic protection of KEYBUS
|
| - |
supervision of AC power loss, low battery, auxiliary power failure
|
- battery required
| - |
12V, 4Ah, rechargeable Gel-Cell
|
- transformer required
- up to 2 partitions
| - |
each partition acts as a separate alarm system with any number of zones, user codes, keypads and individually programmable features
|
- 32 access codes
| - |
each partition can have any number of user codes which may be enabled to operate on one or both partitions
|
| - |
programmable system access by user code
|
| - |
individual open/close reporting by user
|
- automatic arming by partition
| - |
each partition may be programmed to auto-arm at different times |
- 'Quick Arm' and 'Quick Exit'
| - |
allows users to arm and exit easily
|
- Home -Away zones and At-Home arming
| - |
security of perimeter arming while premise is occupied
|
- door chime
| - |
programmable by zone |
| - |
monitor a door by having keypad beep when the door is opened and closed |
- audible exit delay
- audible exit fault
- programmable swinger shut down by zone
- programmable transmission delay by zone
- opening after alarm transmission
Trouble conditions are displayed on all keypads and can also be communicated to central station for :
- low battery
- loss of AC power
- auxiliary power failure
- zone tamper
- siren circuit trouble
- fire circuit trouble
- buffer near full capacity
- failure to communicate
- telephone line trouble - (via links cellular communicator)
- KEYBUS module communication failure
- SG-P5204 power supply module low battery
- SG-P5204 power supply module AC power loss
|
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
The Partner P-832 security system is fully programmable from the attractive, easy to use multi-language SG-P832-LCD keypad:
- multi-language... English, French, Spanish
simple key entry to toggle between languages while viewing keypad
- large 32 character display
| - |
zone identification
|
| - |
system instructions
|
| - |
system status
|
| - |
128 event buffer
|
| - |
trouble conditions
|
- plain language operating instructions
| - |
menu for user functions
|
| - |
what key to press for specific functions
|
| - |
steps for programming functions
|
- 3 LED indicators... Ready, Armed, Trouble
| - |
allows system status to be viewed at a glance
|
- 5 programmable function keys with 18 options such as Home Arm, Away Arm, Quick Exit etc.
- 4 keypad activated alarms... Panic, Emergency, Fire, Duress
- connect up to 8 keypads... any combination of LED and/or LCD
- any keypad can be assigned as 'Global' for system wide control or 'Partition' for operation of a specific partition only
- backlit display
| - |
display and keys backlit for easy viewing in low light conditions
|
- piezo buzzer
| - |
provides audible feedback for correct key entries, pre-alert, and system trouble status
|
- specifications
| - |
current draw... 50mA
|
| - |
4.5"H x 5.5"W x 1"D (11.5 x 14 x 2.6cm)
|
| - |
colour... white
|
The Power832 system is fully programmable from any of the attractive, easy to use, LED keypads:
- 8 zone, 16 zone, and 32 zone keypads
- keypads have 5 programmable function keys with 18 options such as Home Arm, Away Arm, Quick Exit etc.
- connect up to 8 keypads... any combination of LED and/or LCD
- any keypad can be assigned as 'Global' for system wide control
or 'Partition' for operation of a specific partition only
|
|
|
|
- 3 LED indicators... Ready, Armed, Status
| - |
allows system status to be viewed at a glance
|
- 4 keypad activated alarms... Panic, Emergency, Fire, Duress
- backlit display for easy viewing in low light conditions
- piezo buzzer
| - |
provides audible feedback for correct key entries, pre-alert, and system trouble status
|
- specifications
| - |
current draw... 50mA
|
| - |
4.5"H x 5.5"W x 1"D (11.5 x 14 x 2.6cm)
|
| - |
colour... white
|
- turns any touch-tone phone into a fully functional keypad
- built-in power line interface for X-10 control devices
- connect up to 32... X-10 devices
- options include - 'Global' or 'Partition' control
- 8 control groups
- customized commands
- module contains extensive library of voice prompts
| - |
program up to 6 words per label
|
| - |
180 pre-programmed system words
|
| - |
241 pre-programmed library words
|
 |
SG-P5902 Internal Intercom Station
also available:
SG-P5902 EXT ... external intercom station
SG-P5902 EXT/R ... external intercom station with
relay for operation of existing door bell |
- SG-P5908 Audio Interface Module... provides 7 output ports for
connection of SG-P5901 Series Intercom Stations
- local intercom
| - |
page/answer
|
| - |
do not disturb
|
| - |
doorbell function
|
- listen-in broadcast ... allows any station to be a "broadcast station" that may be listened-in to by all other internal stations in the system
- programmable as sounder for fire/burglar alarms
- answer telephone calls received on regular voice line
| - |
supports call waiting
|
| - |
allows call transfer to in-house phones
|
- audio user help
| - |
provides plain language prompts for system programming, operation, and system status reports when installed with SG-P5580 Voice Prompt Module and keypads mounted with SG-P5902 Intercom Stations
|
- central station 2-way listen-in
| - |
programmable control tones (from central station)
|
| - |
select zone, listen/talk, extend on-line time, hang up
|
|
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
- allows serial printer connection for report of events logged to the
system event buffer
- supports any 300, 1200, 2400 or 4800 BPS serial printer
- multiple languages available
- connect module up to 1000' (330m) from control panel
via KEYBUS
- c/w DB-25 modular connector for easy connection
- current draw: 30mA
- maximum one module per system

- add an SG-P5108L... 8 Zone Expander (one only per system)
| - |
adds 8 alarm zones and 8 video inputs (75ohm BNC)
|
- add a DLM-41. Video Transmitter
| - |
provides still-frame video capture, compression, and transmission to a central station equipped with a Sur-Gard MLR2 Digital Receiver and MLRV-A Video Receiver Module
|
- capture video from up to 8 sources including cameras, VCRs, or switchers ... single or quad picture
- program alarm zones (up to 32) to trigger video capture & transmission from any 4 sources in any sequence
- communicates alarm followed by video over a single telephone line in one transmission
- connect modules up to 1000' (330m) from control panel via KEYBUS
- assign zones to one or both partitions
- 25 programmable zone types
- connect up to 1000' (330m) from control panel via KEYBUS
- connect up to 32 wireless devices
- true 'Spread Spectrum' technology, 900 MHz, fully supervised for communication integrity
- 12 minute supervisory time
- easy sensor enroll process
- standard AA/AAA alkaline batteries, 24 to 36 month life
- SG-PWLS908 Wireless Emergency Pendant ... mini 12V battery included
| - |
press 2 buttons for 2 sec. to signal an alarm
|
| - |
up to 32 pendants per system
|
| - |
each occupying one zone
|
- SG-PWLS909 Wireless Key Fob ... mini 12V battery included
| - |
4 buttons for STAY arm, AWAY arm, Disarm, and AUX output (F, A, P, lights, door, etc.)
|
| - |
up to 16 wireless key fobs per system
|
|
|
|
|
- provides 1 A@ 12.5Vdc for additional modules, devices and siren outputs
- includes 4 fully programmable high current outputs
| - |
rated at 1 A @ 12VDC, PTC protected |
- each output programmable to activate for any of 14 options
- one output fully supervised for siren connection
- connect up to 1000' (330m) from control panel via KEYBUS
- fully supervised for low battery and AC power loss
- maximum 1 module per system
|
. . . . . . . . . . . . . . . . . . . . . . . . .
|
- module provides 8 low current transistor switch outputs
| - |
rated at 50mA @ 12.5VDC |
- each output programmable to activate for any of 14 options
- connect up to 1000' (330m) from control panel via KEYBUS
- fully supervised for low battery and AC power loss
- maximum 1 module per system
|
|
| A R C H I T E C T S & E N G I N E E R I N G
S P E C I F I C A T I O N S |
|
|
The contractor shall provide a complete electrically supervised, battery backed-up,
fire and burglary alarm system. The system shall be complete with a multi-zone alarm system with the capability of expansion up to 32
burglar or Class B fire zones of which up to 32 may be wireless zones. All zones shall be supervised and be capable of operating listed
heat detectors, smoke detectors, alarm contacts, motion detectors, vibration detectors and other listed fire and burglary alarm
detection devices. The system shall have expansion capability for up to 8 low current transistor switch outputs; and 4 high current
outputs of which one may be fully supervised for an additional siren. All outputs shall be programmable as 1 of 14 types. System
shall be complete with a 4 wire unshielded (QUAD) communications bus that allows expansion modules for zones and outputs to be
added anywhere on the bus up to 1,000 feet (330m) per leg from the main control panel. The system shall be capable of providing
up to 1.5 amps of 12.5VDC auxiliary power for alarm devices.
The system shall be complete with a built-in power line interface for up to 32 X-10 control devices.
The alarm panel shall be complete with an integrated digital communicator capable of being programmed to transmit to three
separate monitoring stations or locations with 2 account numbers. The communicator shall be capable of supervising the telephone
line; and shall support and supervise LINKS cellular communication with three telephone numbers for backup or sole communications
to monitoring stations and for upload/download operations. The system communicator shall be capable of communicating in all major
formats including SIA and Contact ID. Events transmitted shall be programmable to include: fire alarms, burglary alarms, trouble
alarms, supervisory conditions, alarm restoral codes, opening (disarming) and closing (arming) codes, partial closing codes, and
opening after alarm codes. The system shall be capable of paging personnel on the occurance of any of the above events selected
by the owner. The system shall be capable of transmitting a test code to the monitoring station(s) on a programmable daily,
weekly or monthly frequency at a regular time of day.
The system shall provide video alarm verification to a Sur-Gard MLR2 digital receiver at the central station. System shall
have provision for 8 cameras or video sources with the ability to have any zone activate 4 video sources and initiate video
capture and transmission along with digital transmission of the alarm.
The system shall be complete with audio interface capable of supporting up to 7 audio ports for local intercom/paging,
listen-in broadcast, telephone answering, audio user help, and 2-way listen-in by the monitoring station.
There shall be a 700mA, PTC protected, supervised bell/siren circuit that will drive a bell/siren until reset or silenced.
Siren output shall be programmable as steady or pulsed for each zone.
The alarm panel shall be equipped with EEPROM memory to retain all program information even if all AC and battery power is
lost and shall have integral static and lightning protection circuitry.
The alarm panel shall have SIA false alarm prevention features, programmable swinger shut down by zone, programmable
transmission delay by zone, audible exit delay, audible exit fault, opening after alarm reporting, and "quick exit" to prevent false alarms and unnecessary
transmissions to monitoring stations.
The system shall allow up to 2 "partitions" each acting as a separate alarm system with its own zones, siren output, user
codes and keypads for programming, arming and disarming. Each partition shall be programmable to Auto-Arm at different
times on every day of the week.
The system shall have home-away and at-home arming capability to allow the user
to remain on the premises while the system is armed. A quick-arm feature shall allow users without access codes to arm the
system and exit. A door chime feature shall cause the keypad to beep when a selected door in a partition is opened or secured.
The system shall support any combination of up to 8 "Multi-Language" or "LED"
type keypads with backlit displays. Keypads shall be surface mounted and capable of fully programming and operating the
system. Each keypad shall be assignable to operate the entire system or an individual partition. Multi-Language keypads
shall be complete with 32 character liquid crystal display (LCD) to provide plain language programming instructions,
operating instructions, and display of all alarms and supervisory conditions. They shall be capable of toggling between
English, French and Spanish by pressing a key combination on the keypad. LED keypads shall have 8, 16 or 32 zone
indicators as required.
All keypads shall have keypad activated emergency alarms for fire, auxiliary, panic, and duress; LED indicators for
Ready, Armed, and Trouble or Status; and shall be equipped with a Piezo Buzzer to provide audible feedback for correct
key entries, pre-alert, and trouble. Keypads shall have 5 one-touch function keys capable of being programmed to perform
common user operations such as Home Arm, Away Arm, Quick Exit, etc.
The system shall support wireless emergency pendants for signalling panic alarms; and wireless key fobs for arming,
disarming, and controlling an auxiliary output.
The system shall allow any touch-tone phone to be used as a keypad with programmable voice prompts for system commands,
functions, and labels (zones, etc.).
The system shall allow 32 ... 4 or 6 digit... user codes which may be assigned to one or multiple partitions. The system
shall accommodate 1 -system master code, 2-partition master codes, and 2-duress codes.
The system shall be uploadable/downloadable to allow programming and operation from a remote computer over a telephone
line or LINKS cellular communications equipment. Remote access shall be controlled by the owner to prevent unauthorized
access.
The system shall support a 300, 1200, 2400 or 4800 baud serial printer connected to the communications bus up to 1,000
feet (330m) from the control panel. The printer shall log all system events and transactions with time and date stamp.
Information shall be stored in the systems 128 event buffer which may be examined from the LCD keypad or the DLS software.
The system shall meet UL/ULC standards as required for type of application.
|