SG-P832-LCD Multi-Language Keypad for superior ease of use...
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Trouble conditions are displayed on all keypads and can also be communicated to a central station for:
|
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
DLM-4 Downlook" Video Transmission Module
SG-P5580 Voice Prompt/Security & Building Automation Control Module
SG-P5400 Printer Interface Module
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||
| The contractor shall provide a complete electrically supervised fire and burglar alarm system. The system shall be complete with a multi-zone
alarm system with the capability of programming 6 supervised burg or fire zones and one 2-wire smoke detector zone or auxiliary zone. Programming shall allow a choice of 1 of 21
zone types and 6 zone options for each zone. Zones shall be capable of operating listed heat detectors, smoke detectors, alarm contacts, motion detectors, vibration detectors and other
listed fire and burglary alarm detection devices as required for type of zone. The alarm panel shall have 2 programmable outputs with choice of 1 of 30 output options for each output. The
system shall be capable of providing 500mA of 12Vdc auxiliary power for alarm devices. The system shall be complete with a powerline interface for control of up to 32 X-10 control devices. The alarm panel shall be complete with an integral digital communicator capable of being programmed to transmit to two separate monitoring stations or locations with 2 account numbers. The communicator shall supervise the telephone line. The system shall support and supervise LINKS cellular communications for backup or sole communications to the monitoring stations and/or upload/download operations. The system communicator shall be capable of communicating in 3/1, 3/2, 4/1, or 4/2 20 BPS pulse formats with 1400 or 2300 Hz handshake, Contact ID, SIA, and Pager formats . Events transmitted shall be programmable to include: fire alarms, burglary alarms, trouble alarms, supervisory conditions, alarm restoral codes, opening (disarming) and closing (arming) codes, partial closing codes, and opening after alarm codes. The system shall be capable of paging personnel on the occurance of any of the above events selected by the owner. The system shall be capable of transmitting a manual keypad activated communicator test code and a programmable daily test code to the monitoring station(s) at a regular time of day. The system shall provide video alarm verification to a Sur-Gard MLR2 digital receiver at the central station. System shall have provision for 4 cameras or video sources with the ability to have any zone activate the video sources and initiate video capture and transmission along with digital transmission of the alarm. There shall be a 700mA, current limited at 3 amp, supervised bell/siren circuit that will drive a bell/siren until reset or silenced. Siren output shall be programmable as steady or pulsed for each zone. The alarm panel shall be equipped with EEPROM memory to retain all program information even if AC and battery power is lost; and shall have integral static and lightning protection circuitry. The alarm panel shall have programmable swinger suppression, transmission delay, opening after alarm reporting, audible exit delay with urgency, audible exit fault, and "quick exit" features to prevent false alarms and unnecessary transmissions to monitoring stations. The system shall have "stay" arming capability to allow the user to remain on the premise while the system is armed. A "quick-arm" feature shall allow users without access codes to arm the system and exit. A "quick-exit" feature shall allow a person to leave the armed premise through a delay zone without having to disarm and rearm the system. A door chime feature shall cause the keypad to beep when a selected door (zone) is opened/closed while the system is disarmed. The system shall allow automatic arming at a programmable time of day. The system shall allow 7 access codes plus an installer's programming code. The system shall support up to 8 surface mounted keypads capable of fully programming and operating the system. Keypads shall be any combination of LED or LCD type. LED keypads shall be complete with 6 zone indicator lights and 7 system lights indicating Ready, Armed, Memory, Bypass, Trouble, Program and Fire. LCD keypads shall have multi-language (English, French, Spanish) display capability. Language shall be changeable by customer using a keypad command sequence. LCD keypads shall be complete with liquid crystal display (LCD) to provide plain language programming instructions, operating instructions, and display of all alarms and supervisory conditions; and 3 system lights indicating Ready, Armed, and Trouble. All keypads shall have 5 programmable one-touch function keys, and 3 keypad activated emergency alarms for Panic, Auxiliary, and Fire. Keypads shall be equipped with a piezo buzzer to provide audible feedback for correct key entries, pre-alert, and trouble. The system shall allow any touch-tone phone to be used as a keypad with voice prompts for system commands, functions, and status feedback. The system shall be uploadable/downloadable to allow programming and operation from a remote computer over a telephone line or LINKS cellular communications equipment. Remote access shall be controlled by the owner to prevent unauthorized access. The system shall support a 300, 1200 or 2400 baud serial printer which will print all system events and transactions stored in the systems 100 event memory buffer upon keypad command. User shall have choice of English, French or Spanish language for printout. The system shall meet UL/ULC standards as required for type of application. |
|||
|
|
||